Car-May OEM System Modules
Car-May System Modules are complete fluid delivery
systems for metering and dispensing. These compact
modules precisely move, control, and measure fluid.
|
|
| |
|
|
| |
|
2-Series
Model 2-1
Low-cost metering up to 50 ml/min.
Single-cylinder design; pulsation depends on
control method.
Model 2-4
Dispensing and low-pulsation
metering up to 200 ml/min.
Model 2-4 Nova System
Includes NovaFlow™ for
near-pulseless metering, and NovaSpense™
for dispensing accuracy up to 0.1% Cv. |
| |
|
16-Series
16-series systems are recommended
for applications with higher-viscosity
fluids.
Model 16-2
Dispensing and metering up to 640
ml/min.
Model 16-4
Dispensing and low-pulsation metering
up to 1280 ml/min.
Model 16-4 Nova System
Includes NovaFlow™ for near-pulseless
metering, and NovaSpense™ for dispensing
accuracy up to 0.1% Cv. |
|
|
| |
|
|
| |
| Specifications |
| Nova System Modules |
Model 2-4 |
Model 16-4 |
| Metering |
|
|
| Metering Range |
200 nl/min - 200 ml/min |
1600 nl/min - 1280 ml/min |
| Metering Accuracy |
< 0.5 %Cv |
< 0.5 %Cv |
| NovaFlow™ Metering |
|
|
| Range |
200 nl/min - 20 ml/min |
1600 nl/min - 200 ml/min |
| Accuracy |
< 1 %Cv |
< 1 %Cv |
| Pulsation (%Cv of total flow
at mid range rate) |
3 %Cv |
3 %Cv |
| NovaSpense™ Dispensing |
|
|
| NovaSpense™ Dispensing Accuracy |
0.1 %Cv |
0.1 %Cv |
| NovaSpense™ Dispensing Precision |
0.05 %Cv |
0.05 %Cv |
| Motor: Servo with
features for increased dispensing accuracy-and
near-pulseless metering. |
| Basic System Modules |
Model 2-1 |
Model 2-4 |
Model 16-2 |
Model 16-4 |
| Metering** |
|
|
|
|
| Range w/ stepper motor: integrated motor/driver |
0.2 - 50 ml/min |
.08 - 200 ml/min |
|
|
| Range w/ stepper motor: Two-phase 1.8 degree |
0.2 - 50 ml/min |
6 - 200 ml/min |
25 - 640 ml/min |
50 - 1280 ml/min |
| Accuracy |
< 2 %Cv |
< 2 %Cv |
< 2 %Cv |
< 2 %Cv |
| Dispensing |
|
|
|
|
| Accuracy** |
1-20 %Cv |
1-20 %Cv |
1-20 %Cv |
1-20 %Cv |
| Repeatability |
< 1 %Cv |
< 1 %Cv |
< 1 %Cv |
< 1 %Cv |
| General specs
for all systems |
Model 2-1 |
Model 2-4 |
Model 16-2 |
Model 16-4 |
| Number of cylinders |
1 |
4 |
2 |
4 |
| Displacement volume per cylinder (ml/rev) |
0.2 |
0.2 |
1.6 |
1.6 |
| Displacement total (ml/rev) |
0.2 |
0.8 |
3.2 |
6.4 |
| Pressure max. operating |
125psi (8bar) |
125psi (8bar) |
125psi (8bar) |
125psi (8bar) |
| Manifold Fittings |
1/16" NPT |
1/16" NPT |
1/8" NPT |
1/8" NPT |
| (custom fittings are available) |
1/4"-28 UNF |
1/4"-28 UNF |
1/4" NPT |
1/4" NPT |
| Approx. Dimensions l x w x h (inches) |
5.6 x 2.2 x 2.8 |
7.6 x 2.8 x 2.8 |
9.6 x 5.0 x 5.0 |
9.6 x 5.0 x 5.0 |
| Weight (varys depending on motor type) |
1.6lb (0.7kg) |
3.8lb (1.7kg) |
8.6lb (3.9kg) |
11.1lb (5.0kg) |
|
|
| |
|
|
| |
Dispensing specs are based
on tests with 1.0 mL of RO water at room temperature and
1 atm of pressure.
* Please consult Car-May for information specific to your
application.
* * Specifications are dependent on control system used.
* * * For flow rates of less than 1 mL/min the calculated
instantaneous pulsation levels increase.
Observed pulsation levels depend greatly on fluidic setup
and measurement technique.
Cv: The coefficient of variation, expressed in percent,
is used to describe the standard deviation
(s) relative to the mean (X). Cv = [ (100) (s)/ X ] |
|
| |
|
|
| |
Wetted
Materials
The wetted parts of "Standard configuration"
Car-May System Modules are made from chemically-resistant
materials, creating a versatile, durable fluid control
system. For applications that involve more aggressive
fluids, an even more robust "Inert" wetted parts option
is available. Other options may be available- please
contact us about your 'problem liquid.'
| |
Standard |
Inert |
| Housing |
Delrin (2-series)
Ertalyte or Aluminum (16-series) |
PEEK (2-series)
Ertalyte or Aluminum (16-series) |
| Manifold |
PEEK, Tefzel, or
316L Stainless Steel |
PEEK, Tefzel, or
316L Stainless Steel |
| Manifold O-rings |
Viton |
Perfluoroelastomer |
| Port Plates |
Ceramic Al2O3 |
Ceramic Al2O3 |
| Pistons |
Teflon or UHMW |
Teflon or UHMW |
| Cylinders |
Borosilicate glass (Pyrex) |
Borosilicate glass (Pyrex) |
| Connecting Rods |
PEEK |
PEEK |
 |
|
| |
Nova
System Communications
To harness precision, you must have control.
| |
|
|
|
That's why our Nova Systems have
a flexible communications platform. RS-485 communication
capability allows you to easily control the Nova
Systems with our predefined commands. Use a PC,
PLC, or any other source that can generate 8-bit
ASCII commands to precisely control as many Nova
Systems as you need.
LabVIEW™, C++ and Visual Basic
compatibility provide the versatility required
for simple and effective integration into your
process. Connect the Nova System, assign it to
an address on your network, and you are ready
to go. Up to 250 Modules can be controlled on
one RS-485 network using ASCII serial strings.
Digital I/O and analog capability are standard
in Nova Systems and in Basic Systems that use
the integrated motor/drive. |
|
Move it. Control it. Measure it.
Car-May systems are different from
basic pumps because they do more than typical
pumps. Measurement and flow control capabilities
are incorporated into the pump's design. No external
valves or flow meters are needed.
Four Model 2-1 System Modules
panel-mounted in a standard 19-inch rack |
| |
|
|
|
|
|
|